| Tritex II Accessories & Cables |
| Converters and Splitters |
| USB Port Model TTUSB485 |
USB port to 2 or 4 wire isolated RS-485/422 converter.
Supporting 2-wire RS-485 or a 4-wire RS-422/485 communications, this device is well suited for any application that requires long range or multi-drop capabilities. The TTUSB485 model uses pluggable terminal blocks on the RS-422/485 side and has a pair of LEDs that indicate data being transmitted or received. Model TTUSB485 includes special circuitry that adds 2000 volts isolation protection against ground loops and voltage spikes; and it draws power from the USB port so no power supplies is required.
Simply plug the converter into an available USB port on your computer or USB hub and the device will show up as an additional COM port in the Windows Device Manager. Configured as an additional COM port, the converter is now compatible with your Windows applications.
Universal Serial Bus (USB) has become the connectivity workhorse of today’s PCs, replacing the familiar serial ports. But many commercial and industrial devices still use RS-422/485 interfaces. To connect these devices to modern PCs you need robust and reliable conversion solutions. At the same time, USB ports are becoming more common on commercial and industrial equipment such as point-of-sale peripherals, medical devices, scientific instrumentation, laboratory equipment and other devices. Sometimes these are used in environments where surges, spikes and ground loops are likely to occur.
Features
- 2000 V RMS optical isolation
- 15kV EDS surge protection
- Adds a COM port to your PC
- Protects against surges, spikes and tround loops
- LEDs for transmit and receive lines
- USB 1.0, 1.1 and 2.0 compatible (12 Mbps)
- Automatic configuration on Windows 98, ME, 2000 XP, Vista
- No power supply required (powered from USB bus)
- Includes 1 meter USB cable
RS-485 Control
No special software is required to control the RS-485 receiver or transmit line driver. The driver is automatically enabled during each byte transmitted in RS-485 mode. The transmitter is always enabled in RS-422 mode. The receiver is tri-stated during each byte transmitted in the echo-off mode. The receiver is always enabled in the echo-on mode. There are 4.7k Ohm pull-down resistors on the RDA and RDB lines. A termination resistor may be added to R16 if needed.
Dip Switch Set-up
Dip switches allow the module to be configured for two-wire or four-wire, RS-422 or RS-485 modes. In two-wire mode the TDA (-) and RDA (-) are tied together and so are TDB (+) and RDB (+), making multi-dropping this converter into an existing network easy. |
| Dip Switch Set-Up |
| Switch |
Off |
On |
| One |
TD always enabled (TD 422) |
TD only enabled during data transmission. (TD 485) |
| Two |
RD always enabled (ECHO ON) |
RD disabled during data transmission. (ECHO OFF) |
| Three |
Four-wire mode (4-Wire) |
Two-wire mode (2-Wire) |
| Four |
Four-wire mode (4-Wire) |
Two-wire mode (2-Wire) |
|
Specifications:
Dimensions: 3.5 x 1.7 x 0.8 in (8.9 x 4.3 x 2.1 cm)
Temperature Range: 0 to 70 degrees C (32 to 158 degrees F)
RS-422/485 Baud Rate: Up to 460.8 kbps
RS-422/485 Connector: Pluggable (removable) terminal blocks
USB Baud Rate: 12 Mbps
USB Connector: USB type-B female
USB Power: Low power device (draws < 100mA)
Operating System: Windows 98/SE, 2000, ME, XP, Vista
Accessories: Driver CD, USB Cable
Isolation: 2000 V RMS (excludes model USPTL4)
Surge Protection: 15KV ESD
View Wiring Details
Installation for Windows Instructions
|
Converter
Model TT232485 |
9-Pin RS-232 to RS-422/485 converter. The Model TT232485 is a feature packed RS232 to RS-422/485 9-pin converter. It converts unbalanced, full or half duplex RS-232 signals to balanced, full or half-duplex RS422 or RS-485 signals at baud rates up to 115.2 kbps. In addition, the unit optically isolates and surge suppresses the RS-422/485 lines. The driver uses automatic SD (send data) or TS (handshake) control, or can be configured as always enabled for use in RS-422 systems.
A dipswitch selects communication features on the TT232485. Two LEDs show data traffic in either direction. Only one power supply is necessary, located on the RS-232 side. The isolated power and ground on the RS-422/485 side are generated internally.
Connections are made through a DB9 female connector on the RS-232 side and terminal blocks on the RS-422/485 side. All terminal blocks, dipswitches, and jumpers are located inside the hood and are reachable through the access panel, which slides closed to protect the connections.
The RS-232 port has a DB9 female connector with pins 3 (TD), 2 (RD), and 5 (Signal Ground) supported, pins 7 (RTS) and 8 (CTS) are tied together, and pins 6 (DSR), 1 (CD), and 4 (DTR), are also tied together. The 485OT9L has two LEDs: a Transmit Data LED showing when data goes from the RS-232 side to the RS-485 side, and a Receive Data LED showing data going from the RS-485 side to the RS-232 side. These are very useful for determining if data is getting through the converter. The RS-485 terminal blocks support Transmit Data (A) and (B), Receive Data (A) and (B), and Signal Ground. A single supply voltage of 10 to 30 VDC on the RS-232 side powers the unit. An 8-position dipswitch allows the selection of baud rate, 2-wire or 4-wire mode, echo on or off, and termination in or out.
RS-422/485 Driver Control
The TT232485 uses either RTS Control or Send Data Control to enable the RS-485 driver. This option is user selectable by setting push-on jumpers located next to the terminal blocks. RTS controls the driver using toggling Request to Send (pin 7) of the RS-232 side. Raising RTS enables the driver and lowering RTS disables it. Automatic Send Data Control recognizes the first bit of data from the RS-232 side, enables the transmitter and disables the receiver. After the last bit of data is sent from the RS-232 side, the TT232485 waits one character length then disables the transmitter and enables the receiver. The timeout can be selected with dipswitches or by changing the value of R21 (see Table, Baud Rate Selection). The timeout is preset at the factory for 9600 baud. Removing both sets of jumpers completely will constantly enable the RS-485 driver. This makes the TT232485 behave like an RS-422 converter. For settings, see Table, Standard Communications Settings. settings.
Termination and Echo Options
Termination resistance can be selected with Switch 8 for high baud rates and long cable distances. The 4-wire/2-wire switches (6 and 7) are turned off for 4-wire mode and on for 2-wire mode. When they are set on, they connect TD(A) to RD(A) and TD(B) to RD(B) internally. Switch 5 controls Echo on and off. When switch 5 is in the off position the receiver is constantly enabled. Placing the switch in the on position allows the driver or the receiver to be enabled at any time. In 2-wire mode it is recommended that switch 5 be turned on to prevent data being set out from "echoing" back through the receiver. Up to 32 receivers can be driven by any one RS-485 driver, allowing you to put together large systems with many drop points.
|
| Baud Rate Selection |
| Baud |
Switch 1 |
Switch 2 |
Switch 3 |
Switch 4 |
R21 |
Time out (ms) |
| 1200 |
OFF |
OFF |
OFF |
OFF |
820kOhms |
9.0 |
| 2400 |
OFF |
OFF |
OFF |
OFF |
410kOhms |
4.5 |
| 4800 |
ON |
OFF |
OFF |
OFF |
Not Used |
2.2 |
| 9600 |
OFF |
ON |
OFF |
OFF |
Not Used |
1.1 |
| 19200 |
OFF |
OFF |
ON |
OFF |
Not Used |
0.6 |
| 38400 |
OFF |
OFF |
OFF |
ON |
Not Used |
0.3 |
| 57600 |
OFF |
OFF |
ON |
ON |
Not Used |
0.2 |
| 115200 |
OFF |
OFF |
OFF |
OFF |
8.2 kOhms |
0.1 |
|
| Standard Communications Settings |
| Communication Mode |
JP1 |
Switch 5
Echo |
Switch 6
4W/2W |
Switch 7
4W/2W |
| RS-422 Mode (full duplex) |
Neither |
OFF |
OFF |
OFF |
RS-485 4-Wire Mode
(full duplex) |
RTS or SD |
OFF |
OFF |
OFF |
RS-485 2-Wire Mode
(half duplex) |
RTS or SD |
ON |
ON |
ON |
|
Specifications
Dimensions: 2.7 x 5.1 x 0.9 in (7.0 x 13.0 x 24.0 cm)
Temperature Range: 0 degrees C to 70 degrees C (32 to 158 degrees F)
Supply Voltage: +10 to 30 VDC @ 95 mA maximum
Data Rates: up to 115.2 kbps
Connectors: DB9 female for RS-232. Terminal blocks for RS-422/485 and power
Isolation: 2000 VAC optical isolation of data signals and ground
Surge Suppression: 7.5, bi-directional avalanche breakdown device. 500W peak power dissipation. Clamping time <1 picosecond (theoretical)
View Wiring Detail
View Schematic
|
Splitter
TT485SP |
RS485 Communications splitter. USe to daisy-chain multiple Tritex II actuators. |
|
|
|
|
Tritex II Series Cables
|
Part Number
|
| Raw Power Cable, prepared on one end for use with cable gland GLD-T2M16x1.5 |
CBL-T2IPC-RAW-xxx |
| Raw I/O Cable, prepared on on end for use with cable gland GLD-T2M16x1.5 |
CBL-T2IOC-RAW-xxx |
| Cable Gland - Nickel-plated brass, CE shielding provisions, M20x1.5, for use with above cables |
GLD-T2M20x1.5 |
| M20 x 1.5 to 1/2" NPT threaded hole adapter |
ADAPT-M20-NPT1/2 |
| Communications Cable, PICO type connector, 4 pin, xxx = length in feet. Std lengths 15, 25, 50 feet |
CBL-TTCOM-xxx |
| Power Cables, molded M23 style connector, 6 pin, xxx = length in feet. Std lengths 15, 25, 50 feet |
CBL-T2IPC-SMI-xxx |
| I/O Cables, molded M16 style connector, 19 pin, xxx = length in feet. Std lengths 15, 25, 50 feet |
CBL-T2IOC-SMI-xxx |
| Cable for encoder output of ABZ option board |
CBL-T2ENC-xxx |
| Accessories |
| Communication Cable for use with TT485SP, 6 ft |
CBL-TTDAS-006 |
| Communication Cable for use with TT485SP, 15 ft. |
CBL-TTDAS-015 |
| Port to RS-485/422 Converter |
TTUSB485 |
| RS-232 to RS-422/485 Converter |
TT232485 |
| RS-485 Splitter |
TT485SP |
| Braking Resistor, ESTOP Duty |
T2BR1 |
| Rod Ends and Accessories |
| Clevis Pin for T2M/X090 male "M" rod end 1/2-20 thread |
CP050 |
| Clevis Pin for T2M/X115 male "M" rod end 3/4-15 thread |
CP075 |
| Shperical Rod Eye for T2M/X090 male "M" rod end 1/2-20 thread |
SRM050 |
| Shperical Rod Eye for T2M/X115 male "M" rod end 3/4-16 thread |
SRM075 |
| Rod Eye for T2M/X090 male "M" rod end 1/2-20 thread |
REI050 |
| Rod Eye for T2M/X115 male "M" rod end 3/4-16 thread |
RE075 |
| Rod Clevis for T2M/X090 male "M" rod end 1/2-20 thread |
RCI050 |
| Rod Clevis for T2M/X115 male "M" rod end 3/4-16 thread |
RC075 |
| Jam Nut for T2M/X090 male rod end, 1/2-20 thread |
JAM1/2-20-SS |
| Jam Nut for T2M/X115 male rod end, 1/3-16 thread |
JAM3/4-16-SS |
|
|