Tritex II DC Linear Actuator
Ordering Guide
|
TDM/X Ordering Information |
|
| AAABBB-CCDD-EFG-HH-III-II-JJJ-KKK - (XX..XX - #####) | |
| AAA = Actuator Type | HH = Feedback Type |
| TDM = Tritex II Linear Actuator, standard mechanical capacity | HD = Analog Hall Device |
| TDX = Tritex II Linear Actuator, high mechanical capacity | IE = Incremental Encoder, 8192 count resolution |
| BBB = Actuator Frame Size | AF = Absolute Feedback |
| 060 = 60 mm | III-II = Motor Stator, All 8 Pole |
| 075 = 075 mm | TDM/X060 |
| CC = Stroke Length (nominal) | 1B8-50 = 1 stack, 48 VDC, 5000 rpm |
| 03 = 3 inch (75 mm) | 2B8-50 = 2 stack, 48 VDC, 5000 rpm |
|
06 = 6 inch (150 mm) 10 = 10 inch (250 mm) |
3B8-40 = 3 stack, 48 VDC, 4000 rpm 4 |
| 12 = 12 inch (305 mm) | TDM/X075 |
| 14 = 14 inch (355 mm) (75mm only) | 1B8-30 = 1 stack, 48 VDC, 3000 rpm |
| 18 = 18 inch (455 mm) (75mm only) | 2B8-30 = 2 stack, 48 VDC, 3000 rpm |
| DD = Lead (linear travel per screw revolution) | 3B8-20 = 3 stack, 48 VDC, 2000 rpm 4 |
| 01 = 0.1 inch (2.54 mm)4 | JJJ = Voltage |
| 02 = 0.2 inch (5.08 mm) | 048 = 12-48 VDC |
| 04 = 0.4 inch (10.16 mm) (60 mm only) | KKK = Option Board |
| 05 = 0.5 inch (12.7 mm) (75 mm only) | SIO = Standard I/O Interconnect |
| E = Connections | IA4 = SIO plus isolated 4-20mA Analog I/O |
| G = Standard straight threaded port with internal terminals, M20x1.5 (75 mm only) | EIP = SIO plus Ethernet/IP with M12 connector |
| N = NPT threaded port via adapter with Internal terminals, 1/2" NPT (75 mm only) | PIO = SIO plus Profinet IO with M12 connecctor |
| I = Intercontec style - Exlar std, M23 style connector. | TCP = SIO plus Modbus TCP/IP with M12 connector |
| X = Special (please specify) | EIN = SIO plus Ethernet/IP without M12 connector9 |
| F = Mounting | PIN = SIO plus Profinet IO without M12 connector9 |
| F = Front Flange | TCN = SIO plus Modbus TCP without M12 connector9 |
| R = Rear Flange | X..XX = Travel and Housing Options (Multiple Possible) |
| S = Side Mount | Travel Options |
| J = Metric Side Mount | AR = External Anti-rotate |
| B = Front & Rear Flange | PF = Preloaded Follower 2 |
| C = Rear Clevis | L1/2/3 = External Limit Switches 6 |
| G = Metric Rear Clevis | RB = Rear Brake |
| T = Side Trunnion | SD = Side Manual Drive |
| Q = Metric Side Trunnion | ET = External Linear Transducer |
| E = Extended Tie Rod | HW = Manual Drive Handwheel with limit switch |
| M = Metric Extended Tie Rod | PB = Protective Bellows 8 |
| D = Double Side Mount | SR = Splined Main Rod 7 |
| K = Metric Double Side Mount | XT = Special Travel Options |
| X = Special | Special Motor Options |
| G = Rod End | XL = Special Lubrication Option 5 |
| M = Male US Standard Thread 1 | XM = Special Motor Option |
| A = Male Metric Thread 1 | Housing Options |
| F = Female US Standard Thread 1 | P5 = IP65 sealed housing (TDM only) |
| B = Female Metric Thread 1 | HC = Type III Hard Coat Anodized 3 |
| W = Male, US Standard Thread 17-4 SS | FG = Smooth White Epoxy Coating 3 |
| R = Male Metric Thread 17-4 SS | XH = Special Housing Option |
| V = Female US Standard Thread 17-4 SS | ##### = Part Number Designator forSpecials |
| L = Female Metric Thread 17-4 SS | Optional 5 digit assigned PN to designate unique model numbers |
| X = Special (please specify) | |
| Notes: | |
| 1. Chrome-plated carbon steel. Threads not chrome-plated. | |
| 2. The dynamic load rating of zero backlash, preloaded screws is 63% of the dynamic load rating of the std non-preloaded screws. The calculated travel life of a preloaded screw will be 25% of the calculated travel life of the same size and lead of a non-preloaded screw. | |
| 3. This housing option may indicate the need for special material main rods or mounting. | |
| 4. N/A with 0.1 inch lead, N/A on 3 inch stroke. | |
| 5. To achieve -40 operating temperature, specify -XL in the actuator model mask and define Mobilgrease 28 in order notes. Other special lubricants are also available. | |
| 6. Limit switch option requires AR option. | |
| 7. This option is not sealed in any way. This option is not suitable for any environment in which contaminants come in contact with the actuator, and may enter the actuator. | |
| 8. Not available with extended tie rod mounting option. |
|
| 9. Requires customer supplied Ethernet cable through I/O port for Class I Div 2 compliance only. | |