TDM/X Ordering Information

AAABBB-CCDD-EFG-HH-III-II-JJJ-KKK - (XX..XX - #####)
AAA = Actuator Type HH = Feedback Type
TDM = Tritex II Linear Actuator, standard mechanical capacity HD = Analog Hall Device
TDX = Tritex II Linear Actuator, high mechanical capacity IE = Incremental Encoder, 8192 count resolution
BBB = Actuator Frame Size AF = Absolute Feedback
060 = 60 mm III-II = Motor Stator, All 8 Pole
075 = 075 mm TDM/X060
CC = Stroke Length (nominal) 1B8-50 = 1 stack, 48 VDC, 5000 rpm
03 = 3 inch (75 mm) 2B8-50 = 2 stack, 48 VDC, 5000 rpm

06 = 6 inch (150 mm)

10 = 10 inch (250 mm)

3B8-40 = 3 stack, 48 VDC, 4000 rpm 4
12 = 12 inch (305 mm) TDM/X075
14 = 14 inch (355 mm) (75mm only) 1B8-30 = 1 stack, 48 VDC, 3000 rpm
18 = 18 inch (455 mm) (75mm only) 2B8-30 = 2 stack, 48 VDC, 3000 rpm
DD = Lead (linear travel per screw revolution) 3B8-20 = 3 stack, 48 VDC, 2000 rpm 4
01 = 0.1 inch (2.54 mm)4 JJJ = Voltage
02 = 0.2 inch (5.08 mm) 048 = 12-48 VDC
04 = 0.4 inch (10.16 mm) (60 mm only) KKK = Option  Board
05 = 0.5 inch (12.7 mm) (75 mm only) SIO = Standard I/O Interconnect
E = Connections IA4 = SIO plus isolated 4-20mA Analog I/O
G = Standard straight threaded port with internal terminals, M20x1.5 (75 mm only) EIP = SIO plus Ethernet/IP with M12 connector
N = NPT threaded port via adapter with Internal terminals, 1/2" NPT (75 mm only) PIO = SIO plus Profinet IO with M12 connecctor
I = Intercontec style - Exlar std, M23 style connector.  TCP = SIO plus Modbus TCP/IP with M12 connector
X = Special (please specify)  EIN = SIO plus Ethernet/IP without M12 connector9
F = Mounting PIN = SIO plus Profinet IO without M12 connector9
F = Front Flange TCN = SIO plus Modbus TCP without M12 connector9
R = Rear Flange X..XX = Travel and Housing Options (Multiple Possible)
S = Side Mount Travel Options
J = Metric Side Mount AR = External Anti-rotate
B = Front & Rear Flange PF = Preloaded Follower 2
C = Rear Clevis L1/2/3 = External Limit Switches 6
G = Metric Rear Clevis RB = Rear Brake
T = Side Trunnion SD = Side Manual Drive
Q = Metric Side Trunnion ET = External Linear Transducer
E = Extended Tie Rod HW = Manual Drive Handwheel with limit switch
M = Metric Extended Tie Rod PB = Protective Bellows 8
D = Double Side Mount SR = Splined Main Rod 7
K = Metric Double Side Mount XT = Special Travel Options
X = Special Special Motor Options
G = Rod End XL = Special Lubrication Option 5
M = Male US Standard Thread 1 XM = Special Motor Option
A = Male Metric Thread 1 Housing Options
F = Female US Standard Thread 1 P5 = IP65 sealed housing (TDM only)
B = Female Metric Thread 1 HC = Type III Hard Coat Anodized 3
W = Male, US Standard Thread 17-4 SS FG = Smooth White Epoxy Coating 3
R = Male Metric Thread 17-4 SS XH = Special Housing Option
V = Female US Standard Thread 17-4 SS ##### = Part Number Designator forSpecials
L = Female Metric Thread 17-4 SS Optional 5 digit assigned PN to designate unique model numbers
X = Special (please specify)
Notes:
1. Chrome-plated carbon steel. Threads not chrome-plated.
2. The dynamic load rating of zero backlash, preloaded screws is 63% of the dynamic load rating of the std non-preloaded screws. The calculated travel life of a preloaded screw will be 25% of the calculated travel life of the same size and lead of a non-preloaded screw.
3. This housing option may indicate the need for special material main rods or mounting.
4.  N/A with 0.1 inch lead, N/A on 3 inch stroke.
5. To achieve -40 operating temperature, specify -XL in the actuator model mask and define Mobilgrease 28 in order notes. Other special lubricants are also available.
6. Limit switch option requires AR option.
7. This option is not sealed in any way. This option is not suitable for any environment in which contaminants come in contact with the actuator, and may enter the actuator.
8. Not available with extended tie rod mounting option.
9. Requires customer supplied Ethernet cable through I/O port for Class I Div 2 compliance only.