| FT Series Ordering Info |
| FTAA - BBCC - DEF-GGG - {XX .. .. XX - #####} |
| AA = FT Frame Size |
GGG = Motor Mount Provisions4, 5 (Please indicate the motor that will be used with the FT Actuator by it's 3 digit code.) |
| 35 = 3.5 inch frame actuator |
NMT = No motor mount -- keyed shaft on base unit only |
| |
N23 = NEMA 23 motor mount |
| 60 = 6.0 inch frame actuator |
N34 = NEMA 34 motor mount |
| 80 = 8.0 inch frame actuator |
N42 = NEMA 42 motor mount |
| BB = Stroke Length |
N56 = NEMA 56 motor mount |
| 06 = 6 inch (FT35) |
M60 = Metric 60 mm Exlar standard dimension. Motor not included. |
| 12 = 12 inch (FT35, 60, 80) |
M90 = Metric 90 mm Exlar standard dimension. Motor not included. |
| 18 = 18 inch (FT35) |
M11 = Metric 115 mm Exlar standard dimension. Motor not included. |
| 24 = 24 inch (FT35, 60, 80) |
M14 = Metric 142 mm Exlar standard dimension. Motor not included. |
| 36 = 36 inch (FT35, 60, 80) |
M18 = Metric 180 mm Exlar standard dimension. Motor not included. |
| 48 = 48 inch (FT35, 60, 80) |
G60 = Metric 60 mm Exlar standard dimension. Motor not included |
| CC = Lead |
G90 = Metric 90 mm Exlar standard dimension. Motor not included |
| 05 = 0.2 inch (FT35) |
G11 = Metric 115 mm Exlar standard dimension. Motor not included. |
| 06 = 0.23 inch (FT60, 80) |
AB3,4,6,8 = Allen Bradley Ultra 3, 4, 6, & 8 inch motors |
| 10 = 0.39 inch (FT35) |
BD3,4,6,8 = Baldor 3, 4, 6, & 8 inch motors |
| 12 = 0.47 inch (FT60,80) |
CM3,4,6,8 = Custom Servo Metric 3, 4, 6, & 8 inch motors |
| 20 = 0.79 inch (FT35) |
EE3,4 = Emerson EMC Metric English 3 & 4 inch motors |
| 30 = 1.18 inch (FT60,80) |
EM3,4,6,8 = Emerson EMC Metric 3, 4, 6, & 8 inch Metric motors |
| D= Mounting Style1 |
FA 4,6,8 = Fanuc 4, 6 & 8 inch motors |
| L = Side lugs |
IN3,4,6,8 = Indramat 3, 4, 6, & 8 inch motors |
| B = Front / rear flange (not available with inline motor mount) |
KM2, 4, 6, 8 = Kollmorgen B & M 20, 40, 60 and 80 Series |
| C = Rear clevis (NAW Inline) |
MT3,4,6,8 = Mitsubishi 3,4,6 & 8 inch motors |
| F = Front flange |
PS3,4,6,8 =Pacific Scientific PMA/PMB Series |
| R = Rear flange (not available with inline motor mount) |
PC2,3,4,6 = Parker Compumotor Apex 2.7, 3.6, 4.5, & 5.6 inch |
| S = Side mount |
SM2 = Siemens 2 inch motor
|
| D = Double side mount |
SM3 = Siemens 3 inch motor
|
| E = Extended tie rods |
YS3,4,6,8 = Yaskawa 3, 4, 6, & 8 inch motors |
| T = Side trunnion mount (not available on all sizes and legths) |
MXX Unlisted or special motor mounting provisions |
| J = Metric side mount |
.XX .. XX = Options
|
| K = Metric double side mount |
Mechanical Options |
| Q = Metric side trunnion |
XH = Special housing options |
| M = Metric extended tie rods |
HC = Type III hard coat anodized, class 13 |
| G = Metric rear clevis |
SS = Stainless steel3
|
| X = Special |
XT = High Capacity Roller Screw |
| E = Motor Mounting Configurations |
FG = Smooth white epoxy3 |
| N = None |
(IP65 sealing of unit with motor mounted requires "XH" option)3 |
| I = Inline direct drive (includes Exlar standard coupling) |
Special Follower |
P = Parallel, 1:1 belt reduction
|
PF = Preloaded follower2 |
| Q = Parellel, 2:1 belt reduction |
FX = Special follower |
| X = Special |
End Switches |
| F = Rod End |
L1 = One adjustable switch, (10-30 VDC, PNP, N.C., 1m. 3 wire embedded cable)
|
| M = Male , U.S. standard |
L2 = Two adjustable switches, (10-30 VDC, PNP, N.C., 1m, 3 wire embedded cable)
|
| A = Male, metric |
L3 = Three adjustable switches, (10-30 VDC, PNP, N.C., 1m. 3 wire embedded cable)x |
| F = Female, US standard |
##### = Part No. Designator for Specials |
| B = Female, metric |
Optional 5 digit assigned part number to designate unique PN. |
| W = Male, US std. thread 416Css, rod end only |
|
| R = Male metric thread 4116Css, rod end only |
|
| V = Female, US std thread 416Css, rod end only |
|
| L = Female, metric thread 416CSS, rod end only |
|
| X = Special |
|
| Please provide a drawing of motor dimensions with all orders to insure proper mounting compatibility. |
1. Mounting face size, shaft length and other details of particular motors may require special adapters or provisions for mounting. Always discuss your motor selection with Exlar engineering. |
| 2. This option offers a true zero backlash follower for the FT Series actuator. The dynamic load rating of zero backlash, preloaded screws is 63% of the dynamic load rating of the standard non-preloaded screws. The calculated travel life of a preloaded screw will be 25% of the calculated travel life of the same size and lead of a non-preloaded screw for the same application. Preloaded follower is not available with absolute feedback options. |
| 3. These housing options may also indicate the need for special material main rods, faceplate and motor mounting provisions. Consult Exlar Applications Engineering Department. |
| 4. Max std. motor size FT35: 4 inch/115 mm, FT60 and 80: 8 inch/200 mm. For oversized motors, consult Exlar Applications Engineering. |
| 5. NEMA callout must meet specifications or use alpha-numeric callout. |